KT310-DC
XY Stages
XY stage (ball screw), travel 200 x 200 mm, rep ± 0.7 µm, load 11 kg, speed 60 mm/s
XY stage for universal applications
With a travel of 200 mm in the X and Y directions, the XY stage can be used for all applications, especially for tasks in testing and measurement engineering. Its concept with internal motors, cross roller bearings and high precision ball screws enables excellent precision with optimum use of the installation place.
Specially for measuring applications
|
|
|
Fields of application
Metrology, high-resolution microscopy, biotechnology, medical industry, test engineering, inspection systems
Modell KT310 | -200-DC-R | -200-DC-L | |
Travel | [mm] | 200 | 200 |
Repeatability unidirectional | [μm] | ± 2.5 | ± 0.7 |
Repeatability bidirectional | [μm] | ± 4.5 | ± 1.2 |
Accuracy | [μm] | ± 13.7 | ± 3 |
Flatness | [μm] | ± 4 | ± 4 |
Straightness | [μm] | ± 3 | ± 3 |
Positioning speed | [mm/s] | 30 | 30 |
Max. acceleration | [m/s2] | 0.5 | 0.5 |
Max. load Fx | [N] | 45 | 45 |
Max. load Fy | [N] | 45 | 45 |
Max. load Fz | [N] | 110 | 110 |
Max. torque Mx | [Nm] | 5.3 | 5.3 |
Max. torque My | [Nm] | 5.3 | 5.3 |
Max. torque Mz | [Nm] | 5.1 | 5.1 |
Pitch | [µrad] | ± 140 | ± 140 |
Yaw | [µrad] | ± 70 | ± 70 |
Weight | [kg] | 18 | 18 |
Length | [mm] | 310 | 310 |
Width | [mm] | 310 | 310 |
Height | [mm] | 80 | 80 |
Motor | DC-Motor | DC-Motor | |
Feedback | Motor-Encoder | Linearmesssystem, Linear Scale |
Related Products
Designs for cleanroom, beam and vacuum
Almost all atmospheric standard systems are anodized with UHV lubrication for residual pressures up to 10E-6 mbar and min. cleanroom class ISO 6 - or even better - available.
Overwiew cleanroom & vacuum systems Contact technical consultants
Are you looking for a technical solution for your application?
Get your first 3D Design in a few days:
Elger Matthes
Development, Consulting, Concepts, Innovation
T +49 (0) 351 88585-82 |
Francisco Samuel
Consulting &
Project Management
T +49 (0) 351 88585-85 |
Ronald Schulze
Consulting, Project Management & Engineering
T +49 (0) 351 88585-67 |
Our references